Time is not on our side: what really happens when the fire engine arrives

  •  

Recently, I have found myself at two conferences in the UK where it was suggested that fire engineers needed to spend time with fire services to build their knowledge and understanding. It crystallised a thought on the assumptions made on what happens during a fire and the importance placed by many on the time at which the fire service arrives, writes Tom Roche at the Business Sprinkler Alliance.

There is a period in every industrial or commercial fire incident that many fire incident statistics do not capture. The appliances pull up, crews step out, and from that point on most people assume the fire is being fought. It will be, just not yet.

The government publishes response time data regularly. The latest figures show that the average response time to a primary fire in England is 9 minutes 25 seconds (19 seconds longer than previous year), with around 69% of incidents attended within 10 minutes1. But that clock stops when the first appliance arrives, not when all of them do. What it does not measure is the time between arrival and the moment water actually reaches the fire.

Many sites and building types have a pre-determined attendance, the weight of resources judged necessary to deal with an incident there. An effective response may only be possible once more attendees are at the scene, which means the first appliance arriving marks the start of the build-up, not the start of the firefighting.

We know time matters; catch the fire when it is small and it can be contained. Allow it to continue to develop and the challenge becomes very different. In an industrial or commercial setting, the longer the period before effective intervention, the greater the opportunity for the fire to grow. Designers often discuss guidance on equipment, access and distance. However, what that means for the fire service intervention, and for the fire itself, is perhaps less readily understood.

Appliance access

One of the common themes to my discussions was the positioning of fire appliances relative to the scene. Access is the variable that building owners may spend less time thinking about. A large appliance needs space whether it is to manoeuvre, position, or deploy an aerial platform if required. A delivery lorry parked across a fire access route, a gate that requires a key or bolt cropper to open, a surface that will not take the weight of a fully laden engine: each of these adds more time.

Setting up takes time

The first crew to arrive does not step off the appliance and walk into a burning building. There is equipment to deploy, a cordon to establish, an initial assessment to make. Hoses must be run out and connected. The precise sequence depends on the incident, but none of it is instantaneous. In a straightforward incident with good access it can be achieved relatively quickly. In a large commercial building, an industrial site or premises with difficult access, the challenge can be considerably greater. That is why there is such an important distinction between the time at which the fire service arrives and the time at which effective firefighting intervention begins.

Hydrants and water supply

Securing access to water is one of the most significant constraints.

A fire engine carries a finite amount of water, enough to begin operations, not enough to sustain them. The crew needs to locate a hydrant, confirm it is operational, and run hose to it. In some locations, particularly older industrial estates and rural commercial sites, the nearest hydrant may be some distance away. Even in more modern settings the guidance on hydrant position often leaves a considerable distance between access to water and the fire scene. In some cases it may be an alternative supply like an open body of water, a dry pipe line or a tank. But proximity is only part of the problem.

A report published by the National Fire Chiefs Council in September 20262 found that 81% of UK fire services have had to change their emergency response plans due to concerns over adequate water supplies, with half of those surveyed frequently encountering insufficient flow at hydrants. During the major Stourbridge wildfire in August, it took West Midlands Fire Service 40 minutes to refill a water carrier due to reduced pressure. Every metre of additional hose and every minute lost to inadequate pressure is more time for the fire to grow.

The fire does not wait.

Firefighters cannot rush in

This is perhaps the hardest thing to communicate to those of us outside the service, because every instinct says the opposite. When a building is on fire, the expectation is that trained professionals arrive and they set about controlling the fire. But entering a burning building without proper information is not bravery. It is a risk that serves no one. Crews need to know the layout, the likely seat of the fire, whether anyone is inside, what materials are burning, and whether the structure is safe to enter. Breathing apparatus (BA) must be donned correctly. A BA team and appropriate controls must be in place before entry. All of this takes time. To illustrate this, research3 on fire in purpose built blocks of flats concluded that it could take 20 minutes from arrival before a bridgehead was established to safely deal with a fire on upper floors.

Again this takes time.

None of this is a criticism of the fire service. Quite the opposite. It is recognition of what we ask firefighters to do, the hazards involved and the difference between arriving at a fire and being in a position to fight it effectively.

We are asking more, but are we giving less?

Here is what troubles me. At the same time as public and commercial expectation of the fire service has risen, the conditions in which crews operate have in many cases become harder. The fire load in industrial buildings is growing and warehouses are stacked with materials that burn faster and hotter than anything previous generations of firefighters encountered. And yet we can still design, build and operate commercial premises as though the fire service is a guaranteed backstop, one that will absorb whatever fire safety decisions a building owner chooses not to make.

The government's response time data tells us how quickly help arrives. and that attendance times to primary fires have grown by around a minute in the last 10 years. What the data cannot tell is exactly what happens to a fire in the minutes before water reaches it, or how different that picture might look if suppression had already begun at the point of ignition. However, it does show clearly that there is a strong link between the length of time between ignition and fire service attendance and the reported scale of a fire on arrival.

Analysis of the Incident Recording System dataset, covering 152,134 accidental dwelling fires in England between 2017/18 and 2022/234, found that where the first appliance arrived within five minutes, 8.6% of fires had spread beyond the room of origin, compared with 15.2% where attendance took between 15 and 20 minutes. The proportion causing more than 20m² of damage rose from 4.2% to 9.5% across the same categories, and the pattern held when the analysis was limited to fires discovered and reported promptly. These findings are observational and do not prove causation, but they point in one direction. The bigger we allow a fire to grow before intervention, the poorer the likely outcome.

That data also supports early intervention to arrest the growth of the fire. That is what a sprinkler system does. It does not wait for an appliance to arrive, for hose to be run out, for a hydrant to be located, or for a building to be assessed for safe entry. It operates as soon as the heat from a developing fire reaches the activation temperature of the nearest sprinkler heads, applying water at the source before the gap between arrival and action has had a chance to open.

We ask a great deal of the fire service. The attendance times are increasing and it is time we gave them some additional help with those larger potential incidents: buildings that begin fighting the fire before they do.

For more information about the Business Sprinkler Alliance visit www.business-sprinkler-alliance.org

1https://www.gov.uk/government/statistics/detailed-analysis-of-fires-england-year-ending-march-2026/detailed-analysis-of-fires-and-response-times-to-fires-attended-by-fire-and-rescue-services-england-year-ending-march-2026

2 https://nfcc.org.uk/four-in-five-fire-and-rescue-services-have-changed-emergency-response-plans-due-to-concerns-over-firefighting-water-supplies/

3 London Fire Brigade – Fire Facts: Incident Response Times 2021

4 https://www.gov.uk/government/statistics/fire-statistics-incident-level-datasets

Additional Blogs

How to Turn a Building Condition Assessment into a Phased Works Plan

Your building condition assessment may identify dozens of defects while leaving repair dates and funding decisions unresolved. Turning that assessment into a phased works plan gives you a way to...

Read more

How to Scope Concrete Cutting Services Before Requesting Quotes

Concrete cutting services often become necessary when a building project reaches a point where the existing structure stands in the way of the next stage. A plumber needs a route through the floor...

Read more

The Psychology of Construction and Why We Accept Inefficiency

There is something unusual about the way the construction industry treats problems. A contractor waits three weeks for a drawing. A subcontractor cannot proceed because a specification remains...

Read more

Submit your construction content here

Read more
Top
Login Logo